AICAR 50mg x 10 Vials

$71.26$79.18 (-10%)

In stock

AICAR 50 mg: AICAR is an ambiguous abbreviation in biochemical literature: it can refer to an aminoimidazole-carboxamide riboside or to its phosphorylated nucleotide-related species. These are chemically different reference materials. The abbreviation on a catalogue title is therefore insufficient for assigning one molecular formula with confidence. This listing uses a vial presentation; finished-format specifications must be distinguished from the reference molecule. Intended exclusively for controlled in vitro laboratory research; not for human or veterinary use.

Category:

AICAR 50 mg Australia

AICAR 50 mg is listed at AU Peptides Shop in a vial presentation. This page brings together the compound identity, reference chemistry and laboratory considerations relevant to this specific catalogue entry. It is intended exclusively for controlled in vitro laboratory research, not personal use.

Product description

AICAR is an ambiguous abbreviation in biochemical literature: it can refer to an aminoimidazole-carboxamide riboside or to its phosphorylated nucleotide-related species. These are chemically different reference materials. The abbreviation on a catalogue title is therefore insufficient for assigning one molecular formula with confidence.

Confirm whether the supplied material is Acadesine/AICA riboside or another specified species. A nucleotide formula should not be copied into a riboside listing, and the shared AICAR shorthand should not replace a full chemical name.

Chemical information and molecular structure

Reference designation AICAR
Formula / molecular weight Require a confirmed sequence, chemical form or construct specification; not assigned from the catalogue label.
Sequence information Not applicable to a non-peptide molecular structure.

Reference formula and molecular weight depend on the represented chemical species. Counterions, hydration, oxidation state, terminal modifications and formulation ingredients can change the relationship between a database molecule and the supplied material. Use the named reference species for structural comparison, and use the batch specification for the actual product composition.

Research applications and experimental scope

  • Resolution of riboside versus phosphorylated identity.
  • Nucleotide-related chromatographic analysis.
  • Controlled cellular metabolism experiments.
  • Discrimination of parent compound and related metabolites.

These are laboratory research topics and analytical objectives, not claims that the supplied product has achieved a biological result. Define the experimental question, model and acceptance criteria before comparing materials. A literature observation made with a different sequence, formulation or model cannot establish the performance of this catalogue item.

Analytical characterisation

For AICAR, chromatographic retention and a compatible mass-spectral result can support chemical identification, but neither should be interpreted in isolation. The method should discriminate plausible related substances and the specified salt or redox form where applicable. A peptide sequence assay is not a substitute for small-molecule structural characterisation.

Document whether a reported result is chromatographic area, a calibrated concentration or another defined measurement. Those values are not interchangeable. If the finished presentation contains excipients or other ingredients, assess matrix interference and extraction recovery using a method appropriate to that formulation.

Laboratory model and control considerations

An in vitro experiment with AICAR should distinguish the test-material response from effects of the vehicle, assay matrix and any additional ingredients. Include the controls appropriate to the study design, and keep the reference standard and test sample traceable to their own preparation records. Where a readout depends on cell viability or matrix composition, assess those factors independently of the primary measurement.

Record the sample identity, selected product option, preparation history and analytical method used for the comparison. Repeatability within one run does not by itself establish specificity or transferability to another model. Report observations within the limits of the experimental system rather than treating an in vitro result as evidence of a clinical benefit.

Supplied format and product specifications

Product name AICAR 50 mg
Catalogue format vial presentation
Quantity wording in listing 50 mg
Purity / certification Refer to the relevant batch report; no percentage or certification is assigned without product documentation.

A vial describes packaging, not proof of lyophilisation or a particular solution composition. Where the supplied material is documented as a lyophilized powder, preserve that description and its batch-specific handling requirements. A mass in a title does not establish final solution volume, concentration or solvent compatibility.

Solubility and matrix compatibility

For AICAR, use product-specific solubility information and a laboratory method appropriate to the selected presentation. Apparent dispersion is not necessarily complete dissolution, and a visually clear preparation does not establish chemical stability. Assess recovery and matrix compatibility using the measurement required for your experiment.

Where the product contains additional ingredients, distinguish dissolution of the reference compound from extraction of the finished formulation. Record the documented matrix and any observed interference so another analyst can interpret the result. No universal solvent, solubility limit or preparation protocol is assigned from this catalogue name.

Storage and handling

Use the storage conditions specified for the supplied AICAR 50 mg batch and presentation. A universal freezer temperature, refrigeration interval or prepared-sample expiry is not assigned from the compound name alone. Obtain the relevant product guidance when storage or sample stability is an acceptance criterion for your work.

Maintain traceable labels and document the handling history relevant to the study. Assess changes in appearance, analytical profile or recovery against a validated method rather than assuming that an unchanged label establishes stability. Aseptic laboratory technique does not by itself demonstrate that a research product is sterile; sterility and related quality attributes require their own evidence.

Related catalogue comparisons

  • AICAR — Same named compound(s), different format.

Compare the exact compound, form and quantity in each linked listing. These catalogue relationships do not establish interchangeable materials or recommend combined use.

Australian research enquiries

For AICAR 50 mg in Australia, include the complete listing name, required option and any analytical documentation requirements when you contact AU Peptides Shop. Browse the research catalogue for other individually specified materials. Current purchasing options show price and availability; batch evidence should be reviewed separately.

Scientific references

Research compliance notice

For controlled in vitro laboratory research only. Not for human or veterinary use. This description provides scientific reference information and does not recommend dosing, administration or treatment. Research-use labelling does not establish regulatory approval or permission for a particular activity under Australian therapeutic-goods requirements.

Main Menu